| For the operating parameter applicable to you, as specified in Table 2. . .
| You must establish the following operating parameter limit. . .
| And you must monitor, record, and demonstrate continuous compliance using these minimum frequencies. . .
|
|---|
| Data measurement
| Data recording
| Data averaging period for compliance
|
|---|
| Absorbers
|
| 1. Exit temperature of the absorbing liquid | Maximum temperature | Continuous | Every 15 minutes | 3-hour block average.
|
| 2. Exit specific gravity | Exit specific gravity range | Continuous | Every 15 minutes | 3-hour block average.
|
| Boilers or process heaters
|
| (with a design heat input capacity <44MW and vent stream is not introduced with or as the primary fuel)
|
| 3. Firebox temperature | Minimum firebox temperature | Continuous | Every 15 minutes | 3-hour block average.
|
| Catalytic incinerators
|
| 4. Temperature in gas stream immediately before the catalyst bed | Minimum temperature | Continuous | Every 15 minutes | 3-hour block average.
|
| 5. Temperature difference between the catalyst bed inlet and the catalyst bed outlet | Minimum temperature difference | Continuous | Every 15 minutes | 3-hour block average.
|
| Carbon adsorbers
|
| 6. Total regeneration stream mass flow during carbon bed regeneration cycle(s) | Minimum mass flow during carbon bed regeneration cycle(s) | Continuously during regeneration | Every 15 minutes during regeneration cycle | Total flow for each regeneration cycle.
|
| 7. Total regeneration stream volumetric flow during carbon bed regeneration cycle(s) | Minimum volumetric flow during carbon bed regeneration cycle(s) | Continuously during regeneration | Every 15 minutes during regeneration cycle | Total flow for each regeneration cycle.
|
| 8. Temperature of the carbon bed after regeneration [and within 15 minutes of completing any cooling cycle(s)] | Maximum temperature of the carbon bed after regeneration | Continuously during regeneration and for 15 minutes after completing any cooling cycle(s) | Every 15 minutes during regeneration cycle (including any cooling cycle) | Average of regeneration cycle.
|
| 9. Breakthrough | As defined in § 60.611a | As required by § 60.613a(a)(6)(iii)(B) | Each monitoring event | N/A
|
| Condensers
|
| 10. Exit (product side) temperature | Maximum temperature | Continuous | Every 15 minutes | 3-hour block average.
|
| Scrubbers for halogenated vent streams
|
| 11. pH of scrubber effluent | Minimum pH | Continuous | Every 15 minutes | 3-hour block average.
|
| 12. Influent liquid flow | Minimum inlet liquid flow | Continuous | Every 15 minutes | 3-hour block average.
|
| 13. Influent liquid flow rate and gas stream flow rate | Minimum influent liquid-to-gas ratio | Continuous | Every 15 minutes | 3-hour block average.
|
| Thermal incinerators
|
| 14. Firebox temperature | Minimum firebox temperature | Continuous | Every 15 minutes | 3-hour block average.
|
| Control devices other than an incinerator, boiler, process heater, or flare; or recovery devices other than an absorber, condenser, or carbon adsorber
|
| 15. As specified by the Administrator | As specified by the Administrator | As specified by the Administrator | As specified by the Administrator | As specified by the Administrator. |