As stated in § 63.8806, you must comply with the requirements to demonstrate initial compliance with the applicable emission limits in the following table:
For . . .
| For the following emission limit . . .
| You have demonstrated initial compliance if . . .
|
---|
1. Each new, reconstructed, or existing loop slitter adhesive use affected source | Eliminate use of HAP-based adhesives | You do not use HAP-based adhesives.
|
2. Each new or reconstructed flame lamination affected source using a scrubber | Reduce HAP emissions by 90 percent | The average HAP emissions, measured over the period of the performance test(s), are reduced by 90 percent.
|
3. Each new or reconstructed flame lamination affected source using any other control device emissions by | Reduce HAP emissions by 90 percent | The average HAP emissions, measured over the period of the performance test(s), are reduced by 90 percent.
|
4. Each existing flame lamination affected source | Emit no more than 1.45 pounds per hour of HCl per flame lamination line | The average HCl emissions, measured over the period of the performance test(s) do not exceed 1.45 pounds per hour per flame lamination line. |
[68 FR 18070, Apr. 14, 2003, as amended at 86 FR 64403, Nov. 18, 2021]