As required in § 63.5865, in order to comply with a percent reduction limit or a lbs/ton limit on an averaging basis for continuous lamination lines and continuous casting lines you must determine the data in the following table:
For each . . .
| That . . .
| You must determine . . .
|
---|
1. Wet-out area | Is uncontrolled | Annual uncontrolled wet-out area organic HAP emissions.
|
2. Wet-out area | a. Has an enclosure that is not a PTE | i. The capture efficiency of the enclosure, and
ii. Annual organic HAP emissions that escape the enclosure.
|
3. Wet-out area | Has an enclosure that is a PTE | That the enclosure meets the requirements of EPA Method 204 of appendix M to 40 CFR part 51 for a PTE.
|
4. Oven | Is uncontrolled | Annual uncontrolled oven organic HAP emissions.
|
5. Line | a. Is controlled or uncontrolled | i. The amount of neat resin plus applied, and
ii. The amount of neat gel coat plus applied.
|
6. Add-on control device | | i. Total annual inlet organic HAP emissions, and total annual outlet organic HAP emissions. |