As stated in § 63.2998(c), you must comply with the minimum requirements for monitoring and recordkeeping in the following table:
You must monitor these parameters:
| At this frequency:
| And record for the monitored parameter:
|
---|
1. Thermal oxidizer temperature
1
4 | Continuously | 15-minute and 3-hour block averages.
|
2. Other process or control device parameters specified in your OMM plan
2
4 | As specified in your OMM plan | As specified in your OMM plan.
|
3. Urea-formaldehyde resin solids application rate
4 | On each operating day, calculate the average lb/h application rate for each product manufactured during that day | The average lb/h value for each product manufactured during the day.
|
4. Resin free-formaldehyde content
4 | For each lot of resin purchased | The value for each lot used during the operating day.
|
5. Loss-on-ignition
3
4 | Measured at least once per day, for each product manufactured during that day | The value for each product manufactured during the operating day.
|
6. UF-to-latex ratio in the binder
3
4 | For each batch of binder prepared the operating day | The value for each batch of binder prepared during the operating day.
|
7. Weight of the final mat product per square (lb/roofing square)
3
4 | Each product manufactured during the operating day | The value for each product manufactured during the operating day.
|
8. Average nonwoven wet-formed fiberglass mat production rate (roofing square/h)
3
4 | For each product manufactured during the operating day | The average value for each product manufactured during operating day.
|
[84 FR 6697, Feb. 28, 2019]