Regulations last checked for updates: May 01, 2025

Title 14 - Aeronautics and Space last revised: Apr 02, 2025
§ 25.1017 - Oil lines and fittings.

(a) Each oil line must meet the requirements of § 25.993 and each oil line and fitting in any designated fire zone must meet the requirements of § 25.1183.

(b) Breather lines must be arranged so that—

(1) Condensed water vapor that might freeze and obstruct the line cannot accumulate at any point;

(2) The breather discharge does not constitute a fire hazard if foaming occurs or causes emitted oil to strike the pilot's windshield; and

(3) The breather does not discharge into the engine air induction system.

authority: 49 U.S.C. 106(f), 106(g), 40113, 44701, 44702 and 44704; Pub. L. 115-254, 132 Stat 3281 (49 U.S.C. 44903 note)
source: Docket No. 5066, 29 FR 18291, Dec. 24, 1964, unless otherwise noted.
cite as: 14 CFR 25.1017