Tests required for the certification of each IBC design type are specified in the following table. The letter X indicates that one IBC (except where noted) of each design type must be subjected to the tests in the order presented:
| Performance test
| IBC type
|
|---|
| Metal IBCs
| Rigid plastic IBCs
| Composite IBCs
| Fiber-board IBCs
| Wooden IBCs
| Flexible IBCs
|
|---|
| Vibration |
6 X |
6 X |
6 X |
6 X |
6 X |
1.5 X
|
| Bottom lift |
2 X | X | X | X | X | |
| Top lift |
2 X |
2 X |
2 X | | |
2 5 X
|
| Stacking |
7 X |
7 X |
7 X |
7 X |
7 X |
5 X
|
| Leakproofness |
3 X |
3 X |
3 X | | | |
| Hydrostatic |
3 X |
3 X |
3 X | | | |
| Drop |
4 X |
4 X |
4 X |
4 X |
4 X |
5 X
|
| Topple | | | | | |
5 X
|
| Righting | | | | | |
2 5 X
|
| Tear | | | | | |
5 X
|
[Amdt. 178-108, 60 FR 40039, Aug. 4, 1995, as amended at 64 FR 51919, Sept. 27, 1999; 66 FR 45386, 45390, Aug. 28, 2001]