Regulations last checked for updates: May 09, 2024

Title 40 - Protection of Environment last revised: Jun 26, 2024
§ 426.125 - Standards of performance for new sources.

The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:

(a) Any manufacturing plant which produces incandescent lamp envelopes shall meet the following limitations with regard to the forming operations.

Effluent characteristic Effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed—
Metric units (g/kkg of furnace pull)
Oil90.045.0
TSS90.045.0
pH( 1)( 1)
English units (lb/1,000 lb of furnace pull)
Oil0.090.045
TSS0.090.045
pH( 1)( 1)

1 Within the range 6.0 to 9.0.

(b) Any manufacturing plant which frosts incandescent lamp envelopes shall meet the following limitations with regard to the finishing operations.

Effluent characteristic Effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed—
Metric units (g/kkg of product frosted)
Fluoride104.052.0
Ammonia240.0120.0
TSS80.040.0
pH( 1)( 1)
English units (lb/1,000 lb of product frosted)
Fluoride0.1040.052
Ammonia0.240.12
TSS0.080.04
pH( 1)( 1)

1 Within the range 6.0 to 9.0.

authority: Secs. 301, 304 (b) and (c), 306 (b) and (c), 307(c), and 316(b) of the Federal Water Pollution Control Act, as amended; 33 U.S.C. 1251,1311,1314,1316,1317; 86 Stat. 816
source: 39 FR 2565, Jan. 22, 1974, unless otherwise noted.
cite as: 40 CFR 426.125