Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable:
Subpart I—Metallurgical Acid Plant—BAT Effluent Limitations
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/kg (pounds per/million pounds) of 100 pct sulfuric acid capacity
|
Arsenic | 3.550 | 1.584
|
Cadmium | 0.511 | 0.204
|
Copper | 3.269 | 1.558
|
Lead | 0.715 | 0.332
|
Zinc | 2.605 | 1.073
|
Fluoride
1 | 89.390 | 50.820
|
Molybdenum
1 | [Reserved] | [Reserved].
|
[50 FR 38343, Sept. 20, 1985, as amended at 55 FR 31697, Aug. 3, 1990]
authority: Secs. 301, 304 (b), (c), (e), and (g), 306 (b) and (c), 307 (b) and (c), 308 and 501 of the Clean Water Act (the Federal Water Pollution Control Act Amendments of 1972, as amended by the Clean Water Act of 1977) and the Water Quality Act of 1987 (the “Act”);
33 U.S.C. 1311,
1314,
c,
e,
and, 1316 (b) and
c, 1317 (b) and
c,
1318; 86 Stat. 816, Pub. L. 92-500; 91 Stat. 1567, Pub. L. 95-217; 101 Stat. 7, Pub. L. 100-4
source: 49 FR 8790, Mar. 8, 1984, unless otherwise noted.