Regulations last checked for updates: May 19, 2024

Title 40 - Protection of Environment last revised: May 16, 2024
§ 421.83 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable:

(a) Subpart H—Zinc Reduction Furnace Wet Air Pollution Control.

BAT Effluent Limitations

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of zinc reduced
Cadmium.334.134
Copper2.1351.018
Lead.467.217
Zinc1.702.701

(b) Subpart H—Preleach of Zinc Concentrates.

BAT Effluent Limitations

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of concentrate leached
Cadmium.180.072
Copper1.153.550
Lead.252.117
Zinc.919.378

(c) Subpart H—Leaching Wet Air Pollution Control.

BAT Effluent Limitations

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of zinc processed through leaching
Cadmium.000.000
Copper.000.000
Lead.000.000
Zinc.000.000

(d) Subpart H—Electrolyte Bleed Wastewater.

BAT Effluent Limitations

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of cathode zinc produced
Cadmium.086.035
Copper.553.264
Lead.121.056
Zinc.441.182

(e) Subpart H—Cathode and Anode Wash Wastewater.

BAT Effluent Limitations

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of cathode zinc produced
Cadmium.150.060
Copper.961.458
Lead.210.098
Zinc.766.315

(f) Subpart H—Casting Wet Air Pollution Control.

BAT Effluent Limitations

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of zinc cast
Cadmium.051.021
Copper.329.157
Lead.072.033
Zinc.262.108

(g) Subpart H—Casting Contact Cooling.

BAT Effluent Limitations

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of zinc cast
Cadmium.036.014
Copper.232.110
Lead.051.024
Zinc.185.076

(h) Subpart H—Cadmium Plant Wastewater.

BAT Effluent Limitations

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of cadmium produced
Cadmium1.234.494
Copper7.8993.765
Lead1.728.802
Zinc6.2952.592
authority: Secs. 301, 304 (b), (c), (e), and (g), 306 (b) and (c), 307 (b) and (c), 308 and 501 of the Clean Water Act (the Federal Water Pollution Control Act Amendments of 1972, as amended by the Clean Water Act of 1977) and the Water Quality Act of 1987 (the “Act”); 33 U.S.C. 1311,1314,c,e,and, 1316 (b) andc, 1317 (b) andc,1318; 86 Stat. 816, Pub. L. 92-500; 91 Stat. 1567, Pub. L. 95-217; 101 Stat. 7, Pub. L. 100-4
source: 49 FR 8790, Mar. 8, 1984, unless otherwise noted.
cite as: 40 CFR 421.83