Regulations last checked for updates: May 19, 2024

Title 40 - Protection of Environment last revised: May 16, 2024
§ 147.903 - Existing Class I and III wells authorized by rule.

Maximum injection pressure. The owner or operator shall limit injection pressure to the lesser of:

(a) A value which will not exceed the operating requirements of § 144.28(f)(3) (i) or (ii) as applicable or;

(b) A value for well head pressure calculated by using the following formula:

Pm = (0.733-0.433 Sg)d where: Pm = injection pressure at the well head in pounds per square inch Sg = specific gravity of inject fluid (unitless) d = injection depth in feet.
authority: 42 U.S.C. 300f
source: 49 FR 20197, May 11, 1984, unless otherwise noted.