(a) Approved fire detection and alarm systems must be installed on the following vessels as set forth in subpart 76.27 of this part:
(1) Any vessel on an international voyage;
(2) Any vessel of more than 150 feet (45.72 meters) in length having sleeping accommodations for passengers; and
(3) Any vessel of 150 feet (45.72 meters) or less in length, not on an international voyage, having sleeping accommodations for 50 or more passengers. Vessels in this category are not required to have a fire detection system in the cargo spaces.
(b) The arrangements and details of the fire detection systems must be as set forth in subparts 76.25 through 76.33 of this part.
[USCG-2012-0196, 81 FR 48253, July 22, 2016]
(a) An approved manual alarm system must be installed in all vessels as set forth in subpart 76.27 of this part.
(b) [Reserved]
[USCG-2012-0196, 81 FR 48253, July 22, 2016]
(a) A supervised patrol or watchman system must be provided on all vessels as set forth in §§ 78.30-10 and 78.30-15 of this subchapter.
(b) [Reserved]
[CGFR 65-50, 30 FR 16940, Dec. 30, 1965, as amended by USCG-2012-0196, 81 FR 48253, July 22, 2016]
(a) Fire pumps, hydrants, hose, and nozzles shall be installed on the following vessels:
(1) On all self-propelled vessels.
(2) After July 1, 1957, on all barges with sleeping accommodations for more than six persons.
(b) The arrangement and details of the fire main system shall be as set forth in subpart 76.10.
Approved fire extinguishing systems must be installed, as required by Table 76.05-20 on all self-propelled vessels and on all barges with sleeping accommodations for more than six persons. Previously approved installations may be retained as long as they are maintained in good condition to the satisfaction of the Officer in Charge, Marine Inspection.
Table 76.05-20—Required Fixed Extinguishing Systems
Space
| Fixed extinguishing systems
|
---|
Safety Areas
|
Wheelhouse or fire-control room | None required.
1
|
Stairway and elevator enclosures | None required.
1
|
Communication corridors | None required.
1
|
Lifeboat embarkation and lowering stations | None required.
|
Radio room | None required.
1
|
Accommodations
|
Staterooms, toilet spaces, isolated pantries, etc | None required.
1
|
Offices, lockers, and isolated storerooms | None required.
1
|
Public spaces | None required.
1
|
Open decks or enclosed promenades | None required.
|
Service Spaces
|
Galleys | None required.
1
|
Main pantries | None required.
1
|
Motion picture booths and film lockers | None required.
1
2
|
Paint and lamp rooms | Carbon dioxide.
3
|
Inaccessible baggage, mail, and specie rooms and storerooms | Carbon dioxide.
3
|
Accessible baggage, mail, and specie rooms and storerooms | None required.
1
|
Refrigerated storerooms | None required.
|
Carpenter, valet, photographic, and printing shops, sales rooms, etc | None required.
1
|
Machinery spaces
|
Coal fired boilers: Bunker and boiler space | None required.
1
|
Oil fired boilers: Spaces containing oil fired boilers either main or auxiliary, their fuel oil service pumps, and/or such other fuel oil units as the heaters, strainers, valves, manifolds, etc., that are subject to the discharge pressure of the fuel oil service pumps, together with adjacent spaces to which oil can drain | Carbon dioxide or foam.
4
|
Internal combustion or gas turbine propelling machinery spaces | Carbon dioxide.
5
|
Electric propulsive motors or generators of open type | None required.
|
Enclosed ventilating systems for motors and generators of electric propelling machinery | Carbon dioxide (in ventilating system).
6
|
Auxiliary spaces, internal combustion or gas turbine | Carbon dioxide.
7
|
Auxiliary spaces, electric motors or generators | None required.
|
Auxiliary spaces, steam | None required.
|
Trunks to machinery spaces | None required.
|
Fuel tanks | None required.
8
|
Cargo Spaces
|
Inaccessible during voyage (combustible cargo), including trunks (excluding tanks) | Carbon dioxide.
3
|
Accessible during voyage (combustible cargo) | Automatic or manual sprinkler system.
|
Vehicular deck (except where no overhead deck is 30 feet (9.14 meters) in length or less) | Manual sprinkler.
|
Cargo oil tanks | Carbon dioxide or foam.
3
|
Specially suitable for vehicles | Carbon dioxide, automatic or manual sprinkler system.
|
[USCG-2012-0196, 81 FR 48253, July 22, 2016]
(a) Approved hand portable fire extinguishers and semiportable fire extinguishing systems shall be installed on all vessels as set forth in subpart 76.50.
(b) [Reserved]
authority: 46 U.S.C. 3306; E.O. 12234, 45 FR 58801, 3 CFR, 1980 Comp., p. 277; DHS Delegation No. 00170.1, Revision No. 01.4
source: CGFR 65-50, 30 FR 16940, Dec. 30, 1965, unless otherwise noted.
cite as: 46 CFR 76.05-5