§ 415.420 - Applicability; description of the hydrogen cyanide production subcategory.

This subpart applies to discharges to waters of the United States and introduction of pollutants into publicly owned treatment works resulting from the production of hydrogen cyanide by the Andrussow process.

§ 415.421 - Specialized definitions.

For the purposes of this subpart:

(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.

(b) The term product means hydrogen cyanide.

(c) The term Cyanide A means those cyanides amenable to chlorination and is determined by the methods specified in 40 CFR 136.3.

§ 415.422 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

Subpart AP—Hydrogen Cyanide

Pollutant or pollutant property BPT effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days
Kg/kkg (or pounds per 1,000 lb) of product
TSS8.63.2
Cyanide A0.100.021
Total Cyanide0.650.23
pH( 1)( 1)

1 Within the range 6.0 to 10.5.

§ 415.423 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT):

Subpart AP—Hydrogen Cyanide

Pollutant or pollutant property BAT effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days
Kg/kkg (or pounds per 1,000 lb) of product
Cyanide A0.100.021
Total Cyanide0.650.23
Total Residual Chlorine0.0860.051
§ 415.424 - [Reserved]
§ 415.425 - New source performance standards (NSPS).

Any new source subject to this subpart must achieve the following new source performance standards (NSPS):

Subpart AP—Hydrogen Cyanide

Pollutant or pollutant property NSPS effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days
Kg/kkg (or pounds per 1,000 lb) of product
TSS8.63.2
Cyanide A0.100.021
Total Cyanide0.650.23
Total Residual Chlorine0.0860.051
Ph( 1)( 1)

1 Within the range 6.0 to 10.5.

§ 415.426 - Pretreatment standards for new sources (PSNS).

Except as provided in 40 CFR 403.7, any new source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following Pretreatment Standards for New Sources (PSNS):

Subpart AP—Hydrogen Cyanide

Pollutant or pollutant property PSNS effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days
Milligrams per liter
Cyanide A1.70.36
Total Cyanide114.0
In cases where POTWs find it necessary to impose mass limitations, the following equivalent mass limitations are provided as an alternate: The limitations for Cyanide A and Total Cyanide are the same as specified in § 415.425. [47 FR 55227, Dec. 8, 1982]
§ 415.427 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations are the same for TSS and pH as specified in § 415.422.

authority: Secs. 301, 304 (b), (c), (e), and (g), 306 (b) and (c), 307 (b) and (c), and 501 of the Clean Water Act (the Federal Water Pollution Control Act Amendments of 1972, as amended by the Clean Water Act of 1977) (the “Act”); 33 U.S.C. 1311,1314,c,e,and, 1316 (b) andc, 1317 (b) andc,and; 86 Stat. 816, Pub. L. 92-500; 91 Stat. 1567, Pub. L. 95-217
source: 47 FR 28278, June 29, 1982, unless otherwise noted.