In addition to § 179.200, the individual specification requirements are as follows:
DOT Specification
1
| Insulation
| Bursting pressure (psig)
| Minimum plate
thickness (inches)
| Test
pressure (psig)
| Bottom
outlet
| Bottom
washout
| References (179.201 - ***)
|
---|
111A60ALW1 | Optional | 240 |
1/2 | 60 | Optional | Optional | 6(a).
|
111A60ALW2 | Optional | 240 |
1/2 | 60 | No | Optional.
| |
111A60W1 | Optional | 240 |
7/16 | 60 | Optional | Optional | 6(a).
|
111A60W2 | Optional | 240 |
7/16 | 60 | No | Optional.
| |
111A60W5 | Optional | 240 |
7/16 | 60 | No | No | 3, 6(b).
|
111A60W6 | Optional | 240 |
7/16 | 60 | Optional | Optional | 4, 5, 6(a), 6(c).
|
111A60W7 | Optional | 240 |
7/16 | 60 | No | No | 4, 5, 6(a).
|
111A100ALW1 | Optional | 500 |
5/8 | 100 | Optional | Optional | 6(a).
|
111A100ALW2 | Optional | 500 |
5/8 | 100 | No | Optional.
| |
111A100W1 | Optional | 500 |
7/16 | 100 | Optional | Optional | 6(a).
|
111A100W2 | Optional | 500 |
7/16 | 100 | No | Optional.
| |
111A100W3 | Yes | 500 |
7/16 | 100 | Optional | Optional | 6(a).
|
111A100W4 | Yes (see 179.201-11) | 500 |
7/16 | 100 | No | No | 6(a), 8, 10.
|
111A100W5 | Optional | 500 |
7/16 | 100 | No | No | 3.
|
111A100W6 | Optional | 500 |
7/16 | 100 | Optional | Optional | 4, 5, 6(a) and 6(c).
|
111A100W7 | Optional | 500 |
7/16 | 100 | No | No | 4, 5, 6(c).
|
[Amdt. 179-52, 61 FR 28680, June 5, 1996, as amended by 66 FR 45390, Aug. 28, 2001; 68 FR 48571, Aug. 14, 2003]
source: 29 FR 18995, Dec. 29, 1964, unless otherwise noted. Redesignated at 32 FR 5606, Apr. 5, 1967.
cite as: 49 CFR 179.201-1