Except as provided in § 425.04 and 40 CFR 403.7 and 403.13, any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403, and achieve the following pretreatment standards:
Pollutant or pollutant property
| PSES
|
---|
Maximum for any 1 day
| Maximum for monthly average
|
---|
| Milligrams per liter (mg/l)
|
Sulfide | 24 | |
Total chromium | 12 | 8
|
pH | (
1) | (
1)
|
[47 FR 52870, Nov. 23, 1982, as amended at 61 FR 35685, July 8, 1996]